Clack Settings: Hardness, Regen Day, Regen Time
The following parameters can be changed on the Clack 4-button controller:
Hardness: The hardness value for the water being treated (in Grains Per Gallon)
Regen Days: The maximum number of days between regenerations (aka "Day Override")
Regen Time: The time of day that a regen occurs
To access the menu where the values can be changed, press and hold the NEXT and UP buttons for 3 seconds, then release:
Hardness
- Set the local hardness value in Grains Per Gallon (GPG)
- Convert from mg/L or PPM to GPG by dividing by 17.1
- For every 1.0 mg/L or PPM of iron+manganese, add 3 GPG to the hardness value
Regen Days:
- sets the maximum number of days between regenerations
- Default values for Aquatell softeners as follows:
- Wellmaster = 7 days
- All others - 10 days
- These values should not be adjusted without consulting Aquatell or resin damage may result
Regen Time:
- the time of day that regeneration occurs
- default value is 2:00am
- you can choose any time you want
- during the regeneration, water can be used, but it will not be softened